Platform area with kevlar rolls with vertical movement to adjust to profile heights.
Intensive cooling caps with air/water nebulised
system (nozzles on top under and on each side to cool profile in all faces) with water recovery and cooling system.
Each water flow and air flow can be varied for different profiles.
Vertical movement for puller passage and saw introduction.
Water wave for water dive cooling (water is over profile level).
Cold air ventilating system into caps for air cooling and water elimination.
P.L.C. supervisor control system with various solutions and memorization.
Can work only air, only water, air and water, water wave.
Cooling by means of caps with special air/water atomised and blade nozzles with several independent cooling rows.
Special cold air ventilating system in caps and hot air suction make the system more efficient.
Each cooling cap is 10 m long and up to n° 4 can be put in line. Each cap can work independently.
Vertical movement by means of motor-reductor for puller passage and saw introduction.